Attention!

All contamination limits in this application are in particles/100 mL

Input Values

Standard

Output Values

Cumulative
Standard >1 µm >5 µm >15 µm >25 µm >50 µm >100 µm
>4 µm(c) >6 µm(c) >14 µm(c) >21 µm(c) >38 µm(c) >70 µm(c)
N particles cumulative
ISO 4ed 2021
ISO 1ed 1987
SAE cumulative
Differential
Standard >1 µm
≤5 µm
>5 µm
≤15 µm
>15 µm
≤25 µm
>25 µm
≤50 µm
>50 µm
≤100 µm
>100 µm
>4 µm(c)
≤6 µm(c)
>6 µm(c)
≤14 µm(c)
>14 µm(c)
≤21 µm(c)
>21 µm(c)
≤38 µm(c)
>38 µm(c)
≤70 µm(c)
>70 µm(c)
N particles differential
SAE differential

Reference Tables

Number of particles per 100 millilitre Scale number
More than Up to and including
Contamination Levels >1 µm >5 µm >15 µm >25 µm >50 µm >100 µm
>4 µm(c) >6 µm(c) >14 µm(c) >21 µm(c) >38 µm(c) >70 µm(c)
Contamination Levels >5 µm
≤15 µm
>15 µm
≤25 µm
>25 µm
≤50 µm
>50 µm
≤100 µm
>100 µm
>6 µm(c)
≤14 µm(c)
>14 µm(c)
≤21 µm(c)
>21 µm(c)
≤38 µm(c)
>38 µm(c)
≤70 µm(c)
>70 µm(c)